Why is the difficulty focused on a heptapeptide sample
CAS 80714-61-0 corresponds to Semax (commonly known as brainpower peptide in Chinese), an artificially synthesized linear heptapeptide with the sequence H-Met-Glu-His-Phe-Pro-Gly-Pro-OH, molecular formula C37H51N9O10S, molecular weight of approximately 813.9 Da, and the C-terminal Pro Gly Pro is used to enhance stability.
The difficulty is almost entirely focused on this heptapeptide: methionine (Met) is easily oxidized and produces an oxidized peptide with a molecular weight increase of 16 Da; The missing peptides, truncated peptides, and racemic impurities introduced by synthesis have similar structures and are difficult to separate by chromatography; Peptide bonds require significant UV absorption at around 214 nm, and the detection wavelength and mobile phase need to be specifically optimized; The moisture content and acetate content of freeze-dried powder directly affect the conversion of content.
Projects and basis covered by detection capability
The projects that the laboratory can undertake include characterization and identification, content determination, purity and related substances, amino acid composition, sequence confirmation, secondary structure, moisture and residual solvents, endotoxin and microbial limits, etc. The specific combination is determined according to the sample purpose and judgment standards. Peptide quality control can refer to the relevant general rules and methods of the Chinese Pharmacopoeia and the technical guidance principles of regulatory agencies; The selectivity, linearity, precision, and accuracy of the method were validated according to ICH Q2; The laboratory operates in accordance with the general requirements of ISO/IEC 17025, with instruments regularly calibrated and original records retained.

How to verify methods and equipment
Purity and content are mainly determined by reverse phase high performance liquid chromatography (UV-HPLC): C18 column, water acetonitrile gradient elution, 214 nm detection, main peak area normalization combined with external standard method for quantification; When the separation degree is insufficient, use ultra-high performance liquid chromatography or adjust the mobile phase and column temperature.
Beyond spectrograms: expert teams and method development
The spectrum may match, but the conclusion may not hold true. Peptides containing Met may undergo partial oxidation during sample processing and injection, and both the mobile phase and gradient conditions can affect peak shape and separation. Therefore, method developers need to carefully consider the synthesis route and measured spectra. The laboratory is led by a technical team of doctors and professors responsible for designing detection schemes, analyzing difficult spectra, and interpreting reports. The report also provides data on the purity of the main peak, impurity levels, and structural confirmation, making it easier for the testing party to determine whether the problem lies in synthesis, purification, or storage and transportation.
Visitable laboratories and traceable data
Detection should not be a black box. The laboratory is open for appointment visits, and visitors can follow up on the complete chain of sample acceptance registration, pre-processing, on-board collection, and data review on site. They can check the sample number and retention management, sample weighing and liquid preparation records, as well as the preservation and traceability of chromatographic and mass spectrometry raw data. The location of Hong Kong makes international exchange of samples and reports more convenient.
Appointment for Inspection and Visit
If you also have peptide samples represented by CAS 80714-61-0 that need to be confirmed, please feel free to contact the Hong Kong Peptide Testing Laboratory to discuss the testing items and criteria, or make an appointment to visit the laboratory in person.
The combination of testing items varies with the purpose of the sample: scientific reagent grade focuses more on purity and sequence, while pharmaceutical grade also needs to include indicators such as endotoxins. Before sending for testing, it is advisable to confirm the judgment basis with the laboratory.